As the United States grappled with multiple surges in COVID-19 cases last year, American healthcare facilities adopted crisis capacity decontamination strategies issued by the Center for Disease Control (CDC), including reuse of their N95 masks. Mask cleaning and reuse kept workers and patients safe through supply shortages. But could decontaminating a mask multiple times affect its structure and thus the safety it provides? 51ÁÔÆ桯s dedication to research and humanity inspired us to investigate this question. Equipped with a broad and powerful portfolio of measurement and inspection tools, the 51ÁÔÆæ Instruments team set out to study the effects of disinfection on N95 mask fibers in a series of experiments involving nanoindentation and imaging.

Background

N95 filtering facepiece respirator (FFR) face masks are typically composed of multiple filtration layers. The inner filtration layer is considered the key component in protecting wearers (Figure 1).

Figure 1. The different filtration layers of an N95 face mask. The critical inner layer is made from melt-blown non-woven fabric, which is composed of thousands of very thin, noncontinuous fibrils. Polypropylene is the most widely used raw material for the melt-blown fibrils due to its low melting point.

The National Institute for Occupational Safety and Health (NIOSH) recommends ultraviolet germicidal irradiation (UVGI) to disinfect N95 FFRs for reuse. The necessary UV dose needed to decontaminate the inner mask layer is several hundred times higher than the dose required for virus inactivation in the air or on surfaces. This process may lead to polymer degradation, posing a risk of damage to the N95 respirator materials following multiple decontamination cycles.

Experiment

The 51ÁÔÆæ Instruments team set out to test the nanomechanical and topographic properties of a 3M 9211+ Aura Particulate Disposable Respirator Mask to see if repeatedly disinfecting the mask with ultraviolet C (UVC) light produced changes that suggested a decrease in the mask¡¯s overall effectiveness. After cutting the inner layer of the mask into six 1cm square samples, the scientists placed five of the samples into a chamber and exposed them to UVC light for 5 to 155 minutes. These varied exposure times created five different test conditions. The sixth sample was untreated as a control.

The team used the Nano Indenter? G200X , equipped with the NanoVision option, to help position the measurements accurately and measure force vs. distance curves as a continuous function of penetration depth for multiple individual fibers of the N95 samples (Figure 2). From these measurements, the system determined Young¡¯s modulus and hardness as a function of exposure (Figure 3).

Left: Figure 2. (a) NanoVision image of a polypropylene fiber prior to nanoindentation testing; (b) same fiber after nanoindentation testing, with residual indentation marks highlighted; (c) load-displacement curve for the three indentations; and (d) surface profile along the fiber, showing measured indentation depth and profile location on image.
Right: Figure 3. Hardness (H), Young¡¯s Modulus (E) and fiber width are shown as a function of cumulative UVC dose for N95 polypropylene fibers. The fiber width displays a strong logarithmic decrease with increase in dose.

The researchers followed the nanomechanical measurements with topographic and fiber width measurements using a Zeta-20 optical profiler. The team measured five different sites and five fibers per site for a total of 25 measurements per dose. From the profiler images, they extracted the changes in average fiber width as a function of UVC dose (Figure 4).

Figure 4. Zeta-20 images of the melt-blown layer of the N95 respirator with different UVC doses: (a) 0J/cm2, and (b) 19J/cm2, where the decrease in average fiber width is clearly shown. Z scale is 0¨C160?m for both images and field of view is 374?m x 281?m.

Results

Using 51ÁÔÆ桯s nanoindentation and imaging technology, our researchers were able to gather in-depth measurements on the effects of repeat disinfections on N95 mask fibers. As the world¡¯s healthcare organizations continue to battle COVID-19 and its evolving variants, frontline workers may be asked to reuse personal protective equipment like N95 masks again. Understanding the effects of disinfection on the integrity of N95 mask fibers can help determine the maximum number of disinfections permitted before protection is reduced below required safety levels. Details of the experiment, including relevant data and potential for future research, can be found in the full study, published on MRS Advances. We encourage those interested in performing experiments based on nanoindentation and imaging to browse the 51ÁÔÆæ Instruments website and contact the sales team for more product information.

Subscribe to receive
News from 51ÁÔÆæ

Blog Subscribe
Data Transfer *
Marketing *

Are you sure?

You've selected to view this site translated by Google Translate.
51ÁÔÆæ China has the same content with improved translations.

Would you like to visit 51ÁÔÆæ China instead?


ÄúÒÑÑ¡Ôñ²é¿´ÓɳҴǴDzµ±ô±ð·­Òë·­ÒëµÄ´ËÍøÕ¾¡£
°­³¢´¡ÖйúµÄÄÚÈÝÓëÓ¢ÎÄÍøÕ¾Ïàͬ²¢¸Ä½øÁË·­Òë¡£

ÄãÏë·ÃÎÊ°­³¢´¡ÖйúÂð£¿

If you are a current 51ÁÔÆæ Employee, please apply through the 51ÁÔÆæ Intranet on My Access.

Exit